Membrane filters AE, cellulose nitrate
Applications: - For prefiltration and dust measurement, transparent and sterile filtration
Features: - Highly wettable
- For aqueous solutions
- Hydrophilic
- For use at up to 125°C
- Suitable for autoclaving up to 121°C
- Different pore sizes for a wide range of applications
| | Type | Pore size µm | Ø mm | Order No. | PU pc/Pack | | | AE 100 | 12 | 47 | 26 02 20710 | 100 | | | AE 100 | 12 | 50 | 26 02 20712 | 100 | | | AE 99 | 8 | 25 | 26 02 20605 | 100 | | | AE 99 | 8 | 37 | 26 02 00109 | 100 | | | AE 99 | 8 | 47 | 26 02 20610 | 100 | | | AE 99 | 8 | 50 | 26 02 20612 | 100 | | | AE 99 | 8 | 150 | 26 02 00132 | 25 | | | AE 98 | 5 | 47 | 26 02 20510 | 100 | | | AE 98 | 5 | 50 | 26 02 20512 | 100 | | | ‼ Available only in original packaging units. No fractions possible. |
(1) Membrane filters ME, mixed cellulose ester
Applications: - Ideal for gravimetric analyses
- Particularly suitable for aqueous solutions
- Ideal for contamination tests
Features: - Economic
- Consistent weight
- Hydrophilic
- For use at up to 125°C
- Suitable for autoclaving up to 121°C
| | Type | Pore size µm | Ø mm | Order No. | PU pc/Pack | | | ME 29 | 3 | 25 | 26 02 00706 | 100 | | | ME 29 | 3 | 47 | 26 02 23710 | 100 | | | ME 29 | 3 | 50 | 26 02 23712 | 100 | | | ME 28 | 1.2 | 47 | 26 02 23610 | 100 | | | ME 28 | 1.2 | 50 | 26 02 23612 | 100 | | | ME 27 | 0.8 | 25 | 26 02 23505 | 100 | | | ME 27 | 0.8 | 47 | 26 02 23510 | 100 | | | ME 27 | 0.8 | 50 | 26 02 23512 | 100 | | | ME 25 | 0.45 | 25 | 26 02 23305 | 100 | | | ME 25 | 0.45 | 47 | 26 02 23310 | 100 | | | ME 25 | 0.45 | 50 | 26 02 23312 | 100 | | | ME 25 | 0.45 | 100 | 26 02 01621 | 50 | | | ME 25 | 0.45 | 142 | 26 02 23321 | 25 | | | ME 24 | 0.2 | 25 | 26 02 23105 | 100 | | | ME 24 | 0.2 | 47 | 26 02 23110 | 100 | | | ME 24 | 0.2 | 50 | 26 02 23112 | 100 | | | ME 24 | 0.2 | 142 | 26 02 23121 | 25 | | | ‼ Available only in original packaging units. No fractions possible. |
(2) Membrane filters NC, cellulose nitrate
Applications: - For prefiltration and dust measurement, transparent and sterile filtration
- For filtering aqueous solutions
Features: - Highly wettable
- Hydrophilic
- For use at up to 125°C
- Suitable for autoclaving up to 121°C
| | Type | Pore size µm | Ø mm | Order No. | PU pc/Pack | | | NC 45 | 0.45 | 25 | 26 02 21505 | 100 | | | NC 45 | 0.45 | 47 | 26 02 21510 | 100 | | | NC 45 | 0.45 | 50 | 26 02 21512 | 100 | | | NC 45 | 0.45 | 100 | 26 02 01121 | 50 | | | NC 45 | 0.45 | 142 | 26 02 21521 | 25 | | | NC 20 | 0.2 | 25 | 26 02 21405 | 100 | | | NC 20 | 0.2 | 47 | 26 02 21410 | 100 | | | NC 20 | 0.2 | 50 | 26 02 21412 | 100 | | | NC 20 | 0.2 | 142 | 26 02 21421 | 25 | | | NC 10 | 0.1 | 47 | 26 02 02012 | 100 | | | NC 10 | 0.1 | 50 | 26 02 02014 | 100 | | | ‼ Available only in original packaging units. No fractions possible. |
(3) Membrane filters OE, cellulose acetate
Applications: - Ideal for biological and clinical analyses, sterility tests, scintillation measurements
Features: - Very low protein binder capacity
- Suitable for aqueous and alcohol-based media
- Hydrophilic
- For use up to 180°C, suitable for hot gases
- Suitable for all sterilizing processes
| | Type | Pore size µm | Ø mm | Order No. | PU pc/Pack | | | OE 67 | 0.45 | 25 | 26 02 22305 | 100 | | | OE 67 | 0.45 | 47 | 26 02 22310 | 100 | | | OE 67 | 0.45 | 50 | 26 02 22312 | 100 | | | OE 67 | 0.45 | 100 | 26 02 04021 | 50 | | | OE 67 | 0.45 | 142 | 26 02 22321 | 25 | | | OE 66 | 0.2 | 25 | 26 02 22205 | 100 | | | OE 66 | 0.2 | 47 | 26 02 22210 | 100 | | | OE 66 | 0.2 | 50 | 26 02 22212 | 100 | | | OE 66 | 0.2 | 110 | 26 02 04126 | 50 | | | OE 66 | 0.2 | 142 | 26 02 22221 | 25 | | | ‼ Available only in original packaging units. No fractions possible. |
Membrane filters ME, mixed cellulose ester
Applications: - For microbiological analyses (sterile with mesh)
Features: - With 0.45 µm pore size it provides 100% retention of serratia marcescens.
- 1.2 µm pore size for microbiological yeast tests.
| | Type | Ø mm | Order No. | PU pc/Pack | | | ME 25/21 ST | 50 | 26 02 29705 | 100 | | | ME 24/21 | 50 | 26 02 29504 | 100 | | | ME 24/21 ST | 47 | 26 02 29503 | 100 | | | ME 24/21 ST | 50 | 26 02 29505 | 100 | | | ME 25/41 | 50 | 26 02 29724 | 100 | | | ME 25/41 ST | 50 | 26 02 29725 | 100 | | | ME 25/31 ST | 50 | 26 02 29715 | 100 | | | ‼ Available only in original packaging units. No fractions possible. |
(4) Membrane filters RC, regenerated cellulose
Applications: - For sterile and particle filtering of aqueous and organic solutions
Features: - Spontaneously wettable, high wet strength
- High resistance to chemicals, suitable for aqueous and organic media
- Hydrophilic
- For use up to 180°C
- Suitable for all sterilization processes
- Suitable as a sterile filter according to ASTM-D 3862-80
| | Type | Pore size µm | Ø mm | Order No. | PU pc/Pack | | | RC 60 | 1.0 | 50 | 26 02 10014 | 100 | | | RC 58 | 0.2 | 47 | 26 02 10312 | 100 | | | RC 58 | 0.2 | 50 | 26 02 10314 | 100 | | | RC 55 | 0.45 | 47 | 26 02 10212 | 100 | | | RC 55 | 0.45 | 50 | 26 02 10214 | 100 | | | RC 55 | 0.45 | 100 | 26 02 10219 | 25 | | | RC 55 | 0.45 | 142 | 26 02 10229 | 25 | | | ‼ Available only in original packaging units. No fractions possible. |
Membrane filters TE, PTFE with polyester support
Applications: - Ideal ventilation filter for all applications
- For aggressive media and cryoliquids
- For separating free water from organic solutions
- Particularly suitable as a gas/liquid barrier
- Filtration of air and (hot) gases
Features: - Chemically inert against aqueous and organic solutions and concentrated acids and lyes
- Hydrophobic. For aqueous filtration the pressure must be higher than the water irruption pressure
- For use up to 145°C
- Suitable for all sterilization processes except gamma sterilization
| | Type | Pore size µm | Ø mm | Order No. | PU pc/Pack | | | TE 38 | 5.0 | 47 | 26 02 27510 | 50 | | | TE 38 | 5.0 | 50 | 26 02 27512 | 50 | | | TE 38 | 5.0 | 90 | 26 02 27535 | 25 | | | TE 37 | 1.0 | 25 | 26 02 27405 | 50 | | | TE 37 | 1.0 | 47 | 26 02 27410 | 50 | | | TE 37 | 1.0 | 50 | 26 02 27412 | 50 | | | TE 36 | 0.45 | 47 | 26 02 27310 | 50 | | | TE 36 | 0.45 | 50 | 26 02 27312 | 50 | | | TE 35 | 0.2 | 25 | 26 02 27205 | 50 | | | TE 35 | 0.2 | 47 | 26 02 27210 | 50 | | | TE 35 | 0.2 | 50 | 26 02 27212 | 50 | | | ‼ Available only in original packaging units. No fractions possible. |
Membrane filters NL, polyamide
Made of 100% polyamide. Applications: - General purpose filter, especially suitable for pharmaceuticals
Features: - High mechanical stability
- For aqueous and organic media
| | Type | Pore size µm | Ø mm | Order No. | PU pc/Pack | | | NL 17 | 0.45 | 25 | 26 02 25905 | 100 | | | NL 17 | 0.45 | 47 | 26 02 25910 | 100 | | | NL 17 | 0.45 | 50 | 26 02 25912 | 100 | | | NL 17 | 0.45 | 142 | 26 02 25921 | 25 | | | NL 16 | 0.2 | 47 | 26 02 25810 | 100 | | | ‼ Available only in original packaging units. No fractions possible. |
| 





|