Benchtop Centrifuges ROTINA 420 / 420 R
The compact benchtop centrifuges are designed for a high sample turnover as well as for big sample volumes. With a maximum capacity of 4 × 600 ml, 140 blood sampling devices or 16 micro-titration plates, they are perfectly suitable for use in clinical chemistry, biotechnology and research institutions of the Life Sciences. With impulse key for short centrifugation steps, motor-driven lid lock, 98 programme memories. With the convenient c-control, the parameters can be entered quickly and easily by means of symbol keys and turning knob. Display of current status during operation. | Technical data: | | External dimensions (W×D×H): | 506 × 650 × 423 mm (ROTINA 420) 713 × 654 × 423 mm (ROTINA 420 R) | | Weight: | approx. 75 kg (ROTINA 420) 108 kg (ROTINA 420 R) | | Power supply: | 200 – 240 V, 50/60 Hz (ROTINA 420) 200 – 240 V, 50 Hz (ROTINA 420 R) | | Connected load: | 750 VA (ROTINA 420) 1500 VA (ROTINA 420 R) | | max. speed: | 15000 min-1 | | max. RCF: | 24400 | | max. capacity: | 4 × 600 ml | Emission/ Immunity: | EN/IEC 61326-1, class B | | Cooling ROTINA 420 R: | adjustable from -20°C to +40°C |
| Article | Order No. | | (1) | ROTINA 420, benchtop centrifuge without rotor | 10 56 14701 | | (2) | ROTINA 420 R, benchtop centrifuge without rotor | 10 56 14706 |
Accessories
| Article | Order No. | | (3) | Swing-bucket rotor for max. 4 × 600 ml, without suspension gear | 10 56 14723 | | Round bucket, max. 600 ml, fits in rotor 4723 | 10 56 14750 | | Lid for bucket 4750, with bio-containment | 10 56 14751 | | Suspension gear for plates, fits in rotor 4723 | 10 56 14752 | | (4) | Swing-bucket rotor for max. 4 × 290 ml, without suspension gear | 10 56 14753 | | Round bucket, max. 290 ml, fits in rotors 5694, 4446, 4296, 1798 and 4753 | 55 56 15092 | | Lid for bucket 5092, with bio-containment | 55 56 15093 | | (5) | Swing-bucket rotor for max. 4 × 100 ml, without suspension gear | 10 56 14754 | | Round bucket, alloy, 100 ml, fits in rotor 4754 | 55 56 11430 | | Lid for bucket 1381, 1430 and 1390 | 55 56 11382 | | (6) | Swing-bucket rotor for max. 8 × 50 ml, without suspension gear | 10 56 14758 | | Suspension gear, max. 50 ml, fits in rotor 4758 | 10 56 11746 | | (7) | Fixed-angle rotor for 30 × 1.5/2 ml, with lid, aerosol-tight | 10 56 14790 | | (8) | Fixed-angle rotor for 6 × 0.2 ml 8 PCR strips or 48 × 0.2 ml | 10 56 14760 | | (9) | Lid for rotor 1160 and 4760 | 55 56 11162 | | (AT) | Fixed-angle rotor for max. 4 × 250 ml | 10 56 14795 | | (AK) | Fixed-angle rotor for max. 6 × 94 ml | 10 56 14794 |
Further accessories on request. | 





|