CO2 incubator ICO105, 107 l, 20–50 °C, CO2 control 0–20%

CO2 incubator ICO105, 107 l, 20–50 °C, CO2 control 0–20%
La imagen es solo una referencia, puede diferir e incluir accesorios no disponibles en el producto.
 
Número de artículo.: ICO105 9.814,09 € para 1 Pieza más IVA (21%) más costes de envío
CO2 incubator ICO105; 108 l; working temperature range 5 °C above room temperature to 50 °C; setting temperature range 20 °C to 50 °C; with CO2 control – using dual-beam NDIR measurement – adjustable from 0% to 20%; Humidity limitation via Peltier element; when the water tank is filled and inserted, limits the relative humidity inside the chamber to 93% RH ± 2.5%; electronic microprocessor temperature controller with Pt1000 and self-diagnostic system; fully insulated stainless steel door and inner glass door; 6-sided all-round heating; Stainless steel housing and chamber; with 1 stainless steel water tray; with 1 stainless steel perforated shelf; multiple over-temperature protection/under-temperature alarm; pre-programmed sterilisation programme; factory calibration certificate for +37 °C, 5% CO2; patterned stainless steel housing: 708 x 683 x 586 mm; Stainless steel interior: 560 x 480 x 400 mm; Voltage: 230 V, 50/60 Hz; max. power input: approx. 1450 W
+ info
(-) Compliance information:
WEEE obligation:
WEEE registration number: DE66812464
WEEE brand according to EAR register: Memmert
WEEE type of equipment: Large equipment for use in other than private households only

Options:

  • ICO105B04714
    External measuring instrument with additional measuring head for temperature and
  • ICO105B29744
    Stacking set (4 pcs) for stacking of appliances of same size
  • ICO105B33170
    USB User-ID stick (with User-ID licence): Oven-linked authorisation licence (Use
  • ICO105B33505
    Subframe (622 mm high) adjustable in height (sizes 150/240: should not be used f
  • ICO105B33508
    Subframe (130 mm high); sizes 150/240: only in combination with the correspondin
  • ICO105B38737
    Water dish
  • ICO105B39698
    3 HEPA14-filters (B49800) for chamber according to EN 1822, packed in sterile co
  • ICO105B49800
    HEPA14-filter for chamber according to EN 1822, packed in sterile condition, inc
  • ICO105B6
    Door with lock and key (safety lock)
  • ICO105B8
    Door hinged on the left
  • ICO105C2
    Integrated battery backup: Uninterrupted power supply to the entire display unit
  • ICO105C3
    MobileALERT, notification by SMS in case of any error or alarm of the device (re
  • ICO105C4
    MobileALERT for up to 4 alarm messages (requires option H6 and K6 or K7); alarm
  • ICO105D00106
    Calibration // three CO2 values (5% CO2, 7% CO2, 10% CO2 at +37 °C)
  • ICO105D00124
    IQ/OQ/PQ checklist
  • ICO105D00131
    Calibration // temperature, humidity and CO2 value - freely selectable
  • ICO105D00143
    Calibration // temperature, humidity, CO2 and O2 value - freely selectable
  • ICO105D38897
    IQ/OQ document incl. empty chamber distribution measurement according to DIN 128
  • ICO105DLQ103
    IQ/OQ qualification incl. empty chamber distribution measurement according to DI
  • ICO105DLQ103A
    IQ/OQ qualification // additional temperature, humidity and CO2 value - freely s
  • ICO105DLQ105
    IQ/OQ qualification incl. empty chamber distribution measurement according to DI
  • ICO105DLQ105A
    IQ/OQ qualification // additional temperature, humidity, CO2 and O2 value - free
  • ICO105DLQ200
    PQ qualification; incl. documentation
  • ICO105E02087
    CO2 pressure reducing valve to DIN 8546, incl. gas cylinder monitor
  • ICO105E06189
    Ethernet connection cable 5 m for computer interface
  • ICO105E06192
    USB-Ethernet adapter
  • ICO105E37418
    Perforated stainless steel shelf
  • ICO105E48847
    DAkkS calibration according to method C (DKD-R 5-7) // temperature and humidity
  • ICO105E48848
    DAkkS calibration according to method C/A (DKD-R 5-7) // additional temperature
  • ICO105F7
    Entry port (silicone), 40 mm clear diameter, moisture tight, can be closed by si
  • ICO105FDAQ1
    Basic licence for AtmoCONTROL FDA and myChamber Control FDA. Meets the requireme
  • ICO105GA3Q5
    Warranty extension by 1 year // I: Appliance sizes: 450, 750; ICO: Appliance siz
  • ICO105H6
    Potential-free contact for combination error message (e.g. supply failure, senso
  • ICO105K4
    Heated inner door with partitioned glass doors; sizes 105/150/240 has 2/3/4 part
  • ICO105K5
    Peltier cooling unit enables a working temperature of +37 °C even at higher ambi
  • ICO105K6
    Capacitive humidity sensor for measuring and displaying the relative humidity
  • ICO105K7
    Active microprocessor control for humidifying and dehumidifying (40 - 97 % rh),
  • ICO105S00211
    Calibration // temperature, humidity and CO2 value - freely selectable
  • ICO105S00217
    Calibration // additional temperature, humidity and CO2 value - freely selectabl
  • ICO105S00312
    Maintenance on site; for appliances with active humidity control (option K7)
  • ICO105S00312J
    Maintenance on site (maintenance contract); for appliances with active humidity
  • ICO105S00323
    Maintenance on site; for appliances with passive humidity control
  • ICO105S00323J
    Maintenance on site (maintenance contract); for appliances with passive humidity
  • ICO105T1
    Two gas connections with quick release connectors for automatic switch-over of g
  • ICO105T2
    Electropolished interior
  • ICO105T6
    Control of oxygen concentration by introducing nitrogen; setting range 1–20% O2;
  • ICO105V1
    4 - 20 mA current loop interface; O2 controller, actual value (0 to 25 % O2 = 4
  • ICO105V3
    4 - 20 mA current loop interface; Temperature controller, actual value (0 to +70
  • ICO105V7
    4 - 20 mA current loop interface; Humidity controller, actual value (0 to 100 %
  • ICO105V9
    4 - 20 mA current loop interface; CO2 controller, actual value (0 to 25 % CO2 =
  • ICO105X2
    Voltage 115 V, 50/60 Hz
  • ICO105ZWVR6
    Central water supply, with filter cartridges for connection to the domestic wate
  • ICO105ZWVR7
    Central water supply, without filter cartridges for connection to the domestic w
  • ICO105med
    CO2-Incubator ICO105med, 107l, 18-50°C, CO2 control 0-20%
  • ICO105medB04714
    External measuring instrument with additional measuring head for temperature and
  • ICO105medB29744
    Stacking set (4 pcs) for stacking of appliances of same size
  • ICO105medB33170
    USB User-ID stick (with User-ID licence): Oven-linked authorisation licence (Use
  • ICO105medB33505
    Subframe (622 mm high) adjustable in height (sizes 150/240: should not be used f
  • ICO105medB33508
    Subframe (130 mm high); sizes 150/240: only in combination with the correspondin
  • ICO105medB38737
    Water dish
  • ICO105medB39698
    3 HEPA14-filters (B49800) for chamber according to EN 1822, packed in sterile co
  • ICO105medB49800
    HEPA14-filter for chamber according to EN 1822, packed in sterile condition, inc
  • ICO105medD00124
    IQ/OQ/PQ checklist
  • ICO105medD38897
    IQ/OQ document incl. empty chamber distribution measurement according to DIN 128
  • ICO105medDLQ103
    IQ/OQ qualification incl. empty chamber distribution measurement according to DI
  • ICO105medDLQ103A
    IQ/OQ qualification // additional temperature, humidity and CO2 value - freely s
  • ICO105medDLQ105
    IQ/OQ qualification incl. empty chamber distribution measurement according to DI
  • ICO105medDLQ105A
    IQ/OQ qualification // additional temperature, humidity, CO2 and O2 value - free
  • ICO105medDLQ200
    PQ qualification; incl. documentation
  • ICO105medE02087
    CO2 pressure reducing valve to DIN 8546, incl. gas cylinder monitor
  • ICO105medE06189
    Ethernet connection cable 5 m for computer interface
  • ICO105medE06192
    USB-Ethernet adapter
  • ICO105medE37418
    Perforated stainless steel shelf
  • ICO105medE48847
    DAkkS calibration according to method C (DKD-R 5-7) // temperature and humidity
  • ICO105medE48848
    DAkkS calibration according to method C/A (DKD-R 5-7) // additional temperature
  • ICO105medFDAQ1
    Basic licence for AtmoCONTROL FDA and myChamber Control FDA. Meets the requireme
  • ICO105medGA3Q5
    Warranty extension by 1 year // Im, Um, S: Appliance sizes: 450, 750; ICOmed: Ap
  • ICO105medK4
    Heated inner door with partitioned glass doors; sizes 105/150/240 has 2/3/4 part
  • ICO105medK6
    Capacitive humidity sensor for measuring and displaying the relative humidity
  • ICO105medK7
    Active microprocessor control for humidifying and dehumidifying (40 - 97 % rh),
  • ICO105medS00211
    Calibration // temperature, humidity and CO2 value - freely selectable
  • ICO105medS00217
    Calibration // additional temperature, humidity and CO2 value - freely selectabl
  • ICO105medS00312
    Maintenance on site; for appliances with active humidity control (option K7)
  • ICO105medS00312J
    Maintenance on site (maintenance contract); for appliances with active humidity
  • ICO105medS00323
    Maintenance on site; for appliances with passive humidity control
  • ICO105medS00323J
    Maintenance on site (maintenance contract); for appliances with passive humidity
  • ICO105medT2
    Electropolished interior
  • ICO105medT6
    Control of oxygen concentration by introducing nitrogen; setting range 1–20% O2;
  • ICO105medX2
    Voltage 115 V, 50/60 Hz
  • ICO105medZWVR6
    Central water supply, with filter cartridges for connection to the domestic wate
  • ICO105medZWVR7
    Central water supply, without filter cartridges for connection to the domestic w