Humidity chamber HCP150, 156l, 18-90°C, 20-95%rh
La imagen es solo una referencia, puede diferir e incluir accesorios no disponibles en el producto.
Humidity chamber HCP150, TwinDISPLAY, 156 l, working-temperature range 7 °C above ambient temperature up to 90 °C, setting range 18 °C to 90 °C, active control for humidifying and dehumidifying 20 - 95 % rh, capacitive humidity sensor for measuring and displaying the relative humidity, fully insolated stainless steel door and heated inner glass door, all-round heating on 6 sides, with 2 stainless steel shelves; Ethernet interface for reading out protocol log, USB port on ControlCOCKPIT for use of USB stick, multiple overtemperature protection/undertemperature alarm, works calibration certificate at 60 °C / 75 % rh; textured stainless steel exterior: 719 x 1070 x 591 mm; stainless steel interior: 560 x 700 x 400 mm; voltage: 230 V/ 115V, 50/60 Hz; max. electrical load: approx. 1800 W
+ info | (-) Compliance information: | |
|---|---|
| WEEE obligation: | Sí |
| WEEE registration number: | DE66812464 |
| WEEE brand according to EAR register: | Memmert |
| WEEE type of equipment: | Large equipment for use in other than private households only |
Accesorios:
-
HCP150FDAQ1
Basic licence for AtmoCONTROL FDA and myChamber Control FDA. Meets the requireme -
HCP150B04714
External measuring instrument with additional measuring head for temperature and -
HCP150B33170
USB User-ID stick (with User-ID licence): Oven-linked authorisation licence (Use -
HCP150B33505
Subframe (622 mm high) adjustable in height (sizes 150/240: should not be used f -
HCP150B33508
Subframe (130 mm high); sizes 150/240: only in combination with the correspondin -
HCP150B42114
Stacking set (consisting of stacking corners, one connecting plate for the rear, -
HCP150D00124
IQ/OQ/PQ checklist -
HCP150D00136
IQ/OQ document incl. empty chamber distribution measurement according to DIN 128 -
HCP150E06189
Ethernet connection cable 5 m for computer interface -
HCP150E06192
USB-Ethernet adapter -
HCP150E20165
Stainless steel grid, electropolished -
HCP150E37418
Perforated stainless steel shelf -
HCP150ZWVR6
Central water supply with filter cartridges for connection to the domestic water -
HCP150ZWVR7
Central water supply without filter cartridges for connection to the domestic wa
Options:
-
HCP150C3
MobileALERT, notification by SMS in case of any error or alarm of the device (re -
HCP150C4
MobileALERT for 2 alarm notifications; notification by SMS. temperature and humi -
HCP150D00105
Calibration // temperature and humidity value - freely selectable - HCP150F1
Entry port with 23 mm clear diameter, can be closed, standard position; left cen - HCP150F3
Entry port with 23 mm clear diameter, can be closed, standard position; right ce -
HCP150H6
Potential-free contact for combination error message (e.g. supply failure, senso -
HCP150V3
4 - 20 mA current loop interface; Temperature controller, actual value (0 to +10 -
HCP150V7
4 - 20 mA current loop interface; Humidity controller, actual value (0 to 100 % -
HCP150X2
Voltage 115 V, 50/60 Hz
-
- Fabricante: Memmert
- Artículo-núm.: HCP150
- Categoría: Incubadores refrigerados
Show all Incubadores refrigerados from Memmert - Productos: Cámaras de prueba de clima, Incubadora refrigerada