Humidity chamber HCP150, 156l, 18-90°C, 20-95%rh

Humidity chamber HCP150, 156l, 18-90°C, 20-95%rh
La imagen es solo una referencia, puede diferir e incluir accesorios no disponibles en el producto.
  • (Haga clic aquí para obtener más información)
 
Número de artículo.: HCP150 18.768,16 € para 1 Pieza más IVA (21%) más costes de envío
Humidity chamber HCP150, TwinDISPLAY, 156 l, working-temperature range 7 °C above ambient temperature up to 90 °C, setting range 18 °C to 90 °C, active control for humidifying and dehumidifying 20 - 95 % rh, capacitive humidity sensor for measuring and displaying the relative humidity, fully insolated stainless steel door and heated inner glass door, all-round heating on 6 sides, with 2 stainless steel shelves; Ethernet interface for reading out protocol log, USB port on ControlCOCKPIT for use of USB stick, multiple overtemperature protection/undertemperature alarm, works calibration certificate at 60 °C / 75 % rh; textured stainless steel exterior: 719 x 1070 x 591 mm; stainless steel interior: 560 x 700 x 400 mm; voltage: 230 V/ 115V, 50/60 Hz; max. electrical load: approx. 1800 W
+ info
(-) Compliance information:
WEEE obligation:
WEEE registration number: DE66812464
WEEE brand according to EAR register: Memmert
WEEE type of equipment: Large equipment for use in other than private households only

Accesorios:

  • HCP150FDAQ1
    Basic licence for AtmoCONTROL FDA and myChamber Control FDA. Meets the requireme
  • HCP150B04714
    External measuring instrument with additional measuring head for temperature and
  • HCP150B33170
    USB User-ID stick (with User-ID licence): Oven-linked authorisation licence (Use
  • HCP150B33505
    Subframe (622 mm high) adjustable in height (sizes 150/240: should not be used f
  • HCP150B33508
    Subframe (130 mm high); sizes 150/240: only in combination with the correspondin
  • HCP150B42114
    Stacking set (consisting of stacking corners, one connecting plate for the rear,
  • HCP150D00124
    IQ/OQ/PQ checklist
  • HCP150D00136
    IQ/OQ document incl. empty chamber distribution measurement according to DIN 128
  • HCP150E06189
    Ethernet connection cable 5 m for computer interface
  • HCP150E06192
    USB-Ethernet adapter
  • HCP150E20165
    Stainless steel grid, electropolished
  • HCP150E37418
    Perforated stainless steel shelf
  • HCP150ZWVR6
    Central water supply with filter cartridges for connection to the domestic water
  • HCP150ZWVR7
    Central water supply without filter cartridges for connection to the domestic wa

 

Options:

  • HCP150C3
    MobileALERT, notification by SMS in case of any error or alarm of the device (re
  • HCP150C4
    MobileALERT for 2 alarm notifications; notification by SMS. temperature and humi
  • HCP150D00105
    Calibration // temperature and humidity value - freely selectable
  • HCP150F1
    Entry port with 23 mm clear diameter, can be closed, standard position; left cen
  • HCP150F3
    Entry port with 23 mm clear diameter, can be closed, standard position; right ce
  • HCP150H6
    Potential-free contact for combination error message (e.g. supply failure, senso
  • HCP150V3
    4 - 20 mA current loop interface; Temperature controller, actual value (0 to +10
  • HCP150V7
    4 - 20 mA current loop interface; Humidity controller, actual value (0 to 100 %
  • HCP150X2
    Voltage 115 V, 50/60 Hz