C 1 Package 3/12, Calorimeter, with heater, tap water, halogen resist.
La imagen es solo una referencia, puede diferir e incluir accesorios no disponibles en el producto.
C 1 Package 3/12, Calorimeter, with heater, tap water, halogen resist.
The C 1 static jacket oxygen bomb calorimeter provides a high degree of automation and has the smallest calorimeter footprint available. It operates according to DIN 51900 and ISO 1928. The temperature readings are analyzed according to the classical isoperibol method of Regnault Pfaundler.
With the package 3/12 including C 1.20 water heater it is possible to operate the C 1 with drinking-quality tap water in a temperature range of 5 °C to 25 °C (water temperature < 21°C: measuring mode 22°C/ water temperature > 21 °C: measuring mode 30°C). A chiller is no longer required. The C 1.20 heater serves to maintain the correct temperature of the tap water, which must be connected to the heater at a maximum pressure of 6 bar/0.6 MPa. C 25 pressure regulating gauge is recommended as an accessory if the pressure is higher or cannot be maintained.
The scope of delivery includes all parts necessary to set up the unit. Additionally it includes wear parts and consumables for the first approximately 500 experiments including 25 calibrations. The catalytic activated, halogen resistant combustion chamber C 1.12 is specifically designed for the combustion of samples that contain halogens and sulfur ( > 3 % ). It is equipped with the C 5010.5 large crucible holder and C 6 large quartz crucible.
+ info The C 1 static jacket oxygen bomb calorimeter provides a high degree of automation and has the smallest calorimeter footprint available. It operates according to DIN 51900 and ISO 1928. The temperature readings are analyzed according to the classical isoperibol method of Regnault Pfaundler.
With the package 3/12 including C 1.20 water heater it is possible to operate the C 1 with drinking-quality tap water in a temperature range of 5 °C to 25 °C (water temperature < 21°C: measuring mode 22°C/ water temperature > 21 °C: measuring mode 30°C). A chiller is no longer required. The C 1.20 heater serves to maintain the correct temperature of the tap water, which must be connected to the heater at a maximum pressure of 6 bar/0.6 MPa. C 25 pressure regulating gauge is recommended as an accessory if the pressure is higher or cannot be maintained.
The scope of delivery includes all parts necessary to set up the unit. Additionally it includes wear parts and consumables for the first approximately 500 experiments including 25 calibrations. The catalytic activated, halogen resistant combustion chamber C 1.12 is specifically designed for the combustion of samples that contain halogens and sulfur ( > 3 % ). It is equipped with the C 5010.5 large crucible holder and C 6 large quartz crucible.
| (-) Datos técnicos: | |
|---|---|
| Esterilidad: | No |
| Código EAN: | 4053411053390 |
| (-) Compliance information: | |
|---|---|
| WEEE obligation: | Sí |
| WEEE registration number: | DE66784213 |
Accesorios:
- 0000355100
C 6, Quartz dish, big - 0000749900
C 9, Gelatine capsules - 0000750000
C 10, Acetobutyrate capsules - 0000750200
C 29 (DIN 477), Pressure gauge, oxygen - 0000750600
C 43, Benzoic acid, NIST 39j, 30 g - 0001483500
C 710.2, Set of VA combustion crucibles, big - 0001483700
C 710.4, Cotton thread, cut to length - 0001605300
C 21, Pelleting press - 0001695500
C 4, Quartz dish - 0001749500
C 5, Set of VA combustion crucibles - 0002201400
C 12, Combustion bags, 40 x 35 mm - 0002201500
C 12 A, Combustion bags, 70 x 40 mm - 0003044000
AOD 1.11, Control standard oil for S, Cl, 50 ml - 0003055900
C 5010.5, Crucible holder, big - 0003131100
C 15, Parafilm strips - 0003243000
C 723, Benzoic acid, blister package - 0003717400
C 723 Big Pack, Benzoic acid, blister package - 0003801100
C 16, Parafilm, 1000 x 50 mm - 0003801200
C 17, Paraffin, liquid, 30 ml - 0004040500
C 6040 CalWin, Calorimeter PC software - 0004171000
RC 2 basic, Recirculating chiller - 0004173000
RC 2 control, Recirculating chiller - 0004500200
C 1.123, Ignition wire, platinum - 0004500300
C 1.10, Combustion chamber - 0004500400
C 1.12, Combustion chamber, halogen resistant - 0004500600
C 1.50, Dot matrix printer - 0004500700
C 1.1012, Organizer - 0004500900
C 1.30, Venting station - 0004501000
C 1.20, Water heater - 0004502200
C 1.101, Set of spare parts, approx. 1000 experiments - 0004579300
C 1.103, Ignition wire, standard, Kanthal - 0004579700
C 27, Calorimeter preparation set - 0004579800
C 5010.8, Crucible holder, small - 0004579900
C 710.8, Cotton thread, cut to length, thick - 0010006578
Documents for qualification, for analyzing equipment - 0010006580
Factory Calibration Certificate, for analyzing equipment - 0010006582
IQ/OQ Documentation, for analyzing equipment -
0010010801
Qualification Execution (IQ/OQ), for analyzing equipment - 0010010808
General Certificates (2.2 oder 3.1), for analyzing equipment - 0020014031
C 6000.1, Water protect, 100 ml
-
- Fabricante: IKA
- Artículo-núm.: 0010005638
- Categoría: Calorímetros
Show all Calorímetros from IKA - Validez: 31.10.2026
- Última actualización: 04.06.2026