Página 2 de 2PrimeroAtrás12
Steam Sterilizers, SHP Steriltechnik

Steam Sterilizer LABOKLAV 55 – 195

Installation of the unit as either front- or top loader possible. When set up as front loader the units are stackable. Integrated, separate and powerful steam generator for shorter cycle times.
Low in energy consumption due to optimized size of steam generator in relation to chamber volume.

Steam sterilizer fort he universal use in the laboratory, in full compliance with

  • DIN 58950 (pharmaceutical applications)
  • DIN 58951 (laboratory applications)
  • Pressure Device Directive 2014/68 EU
  • IEC 61010 – 2 - 40 (Thermo locking device)

LABOKLAV 55 – 195
Basic unit with 55, 80, 100, 135, 160 and 195 Litre chamber volume, Useable as either front- or top loader

  • max. permissible pressure 2,8/-1 bar
  • sterilization temperature 98 °C to 135 °C
  • TÜV tested motor-driven safety quick-action lock with lip seal
  • separate integrated latest-generation steam generator with new technology of 4, 6 or 10 kW heating capacity, according to the chamber volume
  • integrated storage tank for fully demineralized water for steam generation (for automatic or manual filling), level monitoring function
  • thermo-lock pursuant to TRB 402 and DIN 61010-2-40
  • flexible PT100 reference sensor for fluid sterilization (time triggered via media temperature)
  • gravitation ventilation and pressure change ventilation (waste sterilization)
  • integrated evaporation condensation, water-cooled, temperature-controlled, adjustable
  • validation adapters
  • internal memory chip for storing up to 150 cycles (may be read out later)
  • RS484 interface for data transmission
  • collective connection to drain pipe
  • floor support inside
  • timer function
  • housing made of powder-coated steel. Choose between 3 color combinations: blue/light gray, emerald/light gray, purple/light gray
  • automatic feed water pump
  • microprocessor control with 20 pre-assigned programs
  • individual assignment of all program slots by the user
  • V4A stainless steel pressure vessel (stainless steel 1.4404 or SS 316L)
  • units with full double jacket made of stainless steel from version M or V
  • easy operation
  • code protected access levels
  • safety chains for a safe state of the unit
  • several cycle data can be documented

Fast Cooling of liquids
All units can be supplied with different cooling versions as an option. The cooling time can be reduced dramatically between 50 and 80%. Main feature to achieve short cooling cycles is the double jacket. VE-Water is pumped through the double jacket during cooling, the full contact surface of the chamber ensures a fast heat transfer into the cooling media. No valuable demineralised cooling water is wasted. The cooling water is fed back into the integrated tank and is reused for the next cycle. Automatic cooling of the VE-Water by means of tap water (heat exchange precept).

Vacuum
A powerful watering vacuum pump guarantees a fast and secure deaeration of the sterilisation goods Fractionated or single pre-vacuum programmes are integrated. If ordered with vacuum system vacuum drying is a standard feature. During the drying vacuum hot steam is pulsed through the double jacket to support the drying process.

 

Available variants of LABOKLAV 55 – 195
B:Basic
M:integrated fast coolling
MS:integrated fast recooling with counter pressure
MSL:integrated fast recooling with counter pressure and additional fan
V:Vacuum system
MV:Vacuum system, integrated fast recooling
MSV:Vacuum system, integrated fast recooling with counter pressure
MSLV:Vacuum system, integrated fast recooling with counter pressure and additional fan


 

TypeChamber-
vol.

l
Chamber-
dimensions
(Ø × T)
mm
Installation space
vertical unit D×W×H1)
(Horizontal unit W×H×D)
mm
Loading
capacity2)
Steam
generator
Electr.
requirements
Laboklav 5555410×460740×765×600
(740×600×765)
approx. 9×1 l Schott4 kW3N 400V~16A
(1N 230V~36A)
Laboklav 8080410×610740×915×600
(740×600×915)
approx. 18×1 l Schott4 kW3N 400V~16A
(1N 230V~36A)
Laboklav 100100410×760740×1065×600
(740×600×1065)
approx. 27×1 l Schott6 kW3N 400V~16A
(1N 230V~36A)
Laboklav 135135510×660840×965×700
(840×700×965)
approx. 30×1 l Schott10 kW3N 400V~16A
(1N 230V~36A)
Laboklav 160160510×760840×1065×700
(840×700×1065)
approx. 45×1 l Schott10 kW3N 400V~16A
(1N 230V~36A)
Laboklav 195195510×990840×1215×700
(840×700×1215)
approx. 45×1 l Schott10 kW3N 400V~16A
(1N 230V~36A)
Technical changes alloed
1)Total height, loading height less 90 mm
2)Front loading approx. 15% less


Type

Order No.TypeOrder No.
55 B10 16 05510135 B10 16 01350
55 M10 16 05511135 M10 16 01351
55 MS10 16 05512135 MS10 16 01352
55 MSL10 16 05513135 MSL10 16 01353
55 V10 16 05514135 V10 16 01354
55 MV10 16 05515135 MV10 16 01355
55 MSV10 16 05516135 MSV10 16 01356
55 MSLV10 16 05517135 MSLV10 16 01357
80 B10 16 08010160 B10 16 01600
80 M10 16 08011160 M10 16 01601
80 MS10 16 08012160 MS10 16 01602
80 MSL10 16 08013160 MSL10 16 01603
80 V10 16 08014160 V10 16 01604
80 MV10 16 08015160 MV10 16 01605
80 MSV10 16 08016160 MSV10 16 01606
80 MSLV10 16 08017160 MSLV10 16 01607
100 B10 16 01000195 B10 16 01950
100 M10 16 01001195 M10 16 01951
100 MS10 16 01002195 MS10 16 01952
100 MSL10 16 01003195 MSL10 16 01953
100 V10 16 01004195 V10 16 01954
100 MV10 16 01005195 MV10 16 01955
100 MSV10 16 01006195 MSV10 16 01956
100 MSLV10 16 01007195 MSLV10 16 01957



Accessories
ArticleOrder No.
Printer for LABOKLAV 55 – 19510 16 02030
Integrated printer for the documentation of all relevant prozcess parameters, real paper printer, stored data can be printed out at a later stage
Touchdisplay10 16 02090
  • Operation possible via touch panel or integrated keypad
  • Documentation available as pdf files via integrated USB port (includes all relevant information such as process and batch data, error messages as well as a graphical analysis which are all combined into a single file protocol for each run)
  • Internal memory saves up to 15.000 cycles
  • Network access via LAN to remotely view live data of the process.
  • Remote maintenance option
Exhaust air filtration10 16 02010
for safety laboratories BSL 2 and 3
Loading system for LABOKLAV 135/16010 16 00160
Comprises the trolley and the loading slide
Loading system for LABOKLAV 19510 16 00195
Comprises the trolley and the loading slide
Lifting device for loading and unloading the LABOKLAV 135 - 19510 16 02040
with swivel arm, for loading and unloading heavy material



Buckets an baskets made of stainless steel on request

vgkl_img

vgkl_img